Engineering Lab Manufacturer,Supplier and Exporter in China
.png)
Product Code : EL-LES-13639
Science kits China is a leading
Engineering Lab Manufacturer,and suppliers in China,
SPECIFICATION
- Analog Input,
- Number of channels-8 differential and 16 single ended
- 16 bit ADC resolution
- DC input coupling
- Input range: -10v to +10v
- Sample Rate maximum- 1 to 1.25 MS/s & no minimum
- 50 ppm of sample rate timing accuracy
- USB signal stream,programmed I/O data transfers. Maximum working voltage for analog inputs ±11V 90 dB CMRR (DC to 60 Hz)
- Less than 1% Accuracy
- Analog edge triggering,analog edge triggering with hysteresis, and analog window triggering modes. Overvoltage Protection (Al±,AISENSE) ±25 V dev.ON
- Scanlist memory: 4095 entries minimum
- 1 analog trigger
- Functions, Start Trigger, ReferenceTrigger, Pause Trigger, Sample Clock, Convert Clock, Sample Clock Timebase Number of counters/timers-2
- 32 bit counter resolution
- 1 Mhz frequency
- 2 No of waveform generator Output range ±10 V,±5V
- DC output coupling
- DMM functions- DC voltage, AC voltage, DC current, AC current, resistance and diode
- DMM Resolution - 5.5 digits
- DC Voltage measurement range- 100mV to 60V
- AC Voltage measurement range-200 mV-20 Vrms
- DC and AC current range-0 to 2A max
- 2 channel Oscilloscope and simultaneous sampling mode
- AC,DC,GND input coupling
- Power source - 15v to +15v dc
- USB 2.0 Hi-Speed bus interface communicationAnalog Input,
- Number of channels-8 differential and 16 single ended
- 16 bit ADC resolution
- DC input coupling
- Input range: -10v to +10v
- Sample Rate maximum- 1 to 1.25 MS/s & no minimum
- 50 ppm of sample rate timing accuracy
- USB signal stream,programmed I/O data transfers. Maximum working voltage for analog inputs ±11V 90 dB CMRR (DC to 60 Hz)
- Less than 1% Accuracy
- Analog edge triggering,analog edge triggering with hysteresis, and analog window triggering modes. Overvoltage Protection (Al±,AISENSE) ±25 V dev.ON
- Scanlist memory: 4095 entries minimum
- 1 analog trigger
- Functions, Start Trigger, ReferenceTrigger, Pause Trigger, Sample Clock, Convert Clock, Sample Clock Timebase Number of counters/timers-2
- 32 bit counter resolution
- 1 Mhz frequency
- 2 No of waveform generator Output range ±10 V,±5V
- DC output coupling
- DMM functions- DC voltage, AC voltage, DC current, AC current, resistance and diode
- DMM Resolution - 5.5 digits
- DC Voltage measurement range- 100mV to 60V
- AC Voltage measurement range-200 mV-20 Vrms
- DC and AC current range-0 to 2A max
- 2 channel Oscilloscope and simultaneous sampling mode
- AC,DC,GND input coupling
- Power source - 15v to +15v dc
- USB 2.0 Hi-Speed bus interface communication